Tube tests NANOCOLOR® Ammonium

Description
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.

Hazardous Substance Data
GHS
Signal word
Achtung
H-Satz
H302, H315, H319
P-Satz
P264W, P280sh, P301+P312, P330
SDS
Link
Properties
Description: Ammonium 100
GHS: GHS07
Manufacturer Article Number: 985008
Measuring range: 4 - 80 mg/l NH4-N5 - 100 mg/l NH4+
UNSPSC: 41-11-61-16
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From €80.80*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From €74.00*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From €85.70*

Photometers MD 100
The Lovibond® MD 100 Photometers are designed for analysis of different parameters in drinking water, industrial process water and waste water. With a total of more than 30 different types, instruments are available for routine testing as well as for special applications. The MD 100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling. Provided with calibration and software-based adjustment options the MD 100 is suitable for use as a testing instrument. The tests are conducted using either Lovibond® tablet reagents with long-term stability and a shelf life of 5 or 10 years, VARIO powder reagents or using liquid reagents.Optics: High-quality Interference FiltersWavelength accuracy: ±1 nm.Power supply: 4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests.Automatic switch-off.LCD Display (backlit on keypress).Internal ring memory for 16 data sets.Dimensions (L x W x H): 155 x 75 x 35 mm.Scope of supply: Photometer in a plastic carrying case, with reagents for 100 tests, cells, batteries and standard accessories.Optional: IRiM - infrared interface module for data transfer to computer or printer.*Delivery without reagents for measuring range 0.1 - 10 mg/l Cl2.**24mm diam. glass cell***10mm diam. multi cell-2
From €516.10*

Accessories NANOCOLOR®
*additional cable required**additional mains adapter required
From €9.10*

Photometer MD50
Single-parameter photometer for analysing various parameters in water treatment. The device contains pre-programmed methods for different types of reagents. With the One-Time-Zero function, the device only needs to be zeroed once per sample. Data can be easily transferred to the AquaLX® app via NFC or to the PC software using a USB cable.Robust, ergonomic design with rubber-protected sides for a firm gripDisplay with coloured backlight shows the status of results and errorsLanguage-free user interface with icons and animationsAccurate and reproducible resultsOne-point calibrationProgramming option for one customised methodNFC data transmissionUSB-C connectionAutomatic storage of the last 100 readings and protocols with time and date stampGLP compliant data backupScope of supply: Photometer, 3 x 24 mm round glass cuvettes with lid and sealing ring, screwdriver, 3 x stirring rods, 10 ml syringe, cleaning brush, USB-C to USB-A cable, carrying case, 2 x AA batteries, operating instructions, reagents (depending on variant)
From €480.00*

Photometer MD50 COD
The MD50 COD is specifically designed for COD determination and offers superior performance, enhanced usability and expanded testing capabilities, including the new Very Low Range (VLR) COD method for ultra-sensitive measurements.Highest accuracy for low-pollution samplesMeasurement of COD in high, medium and very low ranges for versatile applicationsEasy operation thanks to intuitive symbols and animations as well as user-friendly navigationResults within seconds enable high efficiencyTime saving with the One Time Zero function (stays valid for up to 8 hours)Handheld design for comfortable single-handed operationRobust housing with side protection for extra durabilityWireless NFC and USB-C data transferAutomatic GLP complianceVersatile connectivity via the AquaLX® app or Lovibond® Data Expert softwarePre-programmed Lovibond® CSB cuvette tests for operation right out of the box available separatelyMethods: M134, M130, M133, M131, M132Scope of supply: Photometer in carrying case, adapter for cells (16 mm), 2 x dosing syringes (1 ml, 2 ml), USB-C cable, screwdriver, manual, 2 x AA batteries
From €331.65*

Photometer MD150 Cl-pH, with liquid reagents
Single-parameter photometer for analysing various parameters in water treatment. The innovative optics achieves fast, high-precision measurements. The device contains pre-programmed methods for different types of reagents. With the One-Time-Zero function, the device only needs to be zeroed once per sample. Data can be easily transferred to the AquaLX® app via NFC or to the PC software using a USB cable. Robust, ergonomic design with rubber-protected sides for a firm gripDisplay with coloured backlight shows the status of results and errorsLanguage-free user interface with icons and animationsAccurate and reproducible resultsAbsorbance measurement possibleProgramming option for one customised methodOption to customise methods list based on reagent typeNFC data transmissionUSB-C connectionAutomatic storage of the last 100 readings and protocols with time and date stampGLP compliant data backupMethods: M100, M101, M103, M110, M112, M330, M331Scope of supply: 3 x 24 mm vials with lid, 3 x stirring rods, syringe, cleaning brush, screwdriver, USB-C to USB-A cable, instruction manual, reagents, 2 x AA batteriesSingle-parameter photometer for analysing various parameters in water treatment. The innovative optics achieves fast, high-precision measurements. The device contains pre-programmed methods for different types of reagents. With the One-Time-Zero function, the device only needs to be zeroed once per sample. Data can be easily transferred to the AquaLX® app via NFC or to the PC software using a USB cable. Robust, ergonomic design with rubber-protected sides for a firm gripDisplay with coloured backlight shows the status of results and errorsLanguage-free user interface with icons and animationsAccurate and reproducible resultsAbsorbance measurement possibleProgramming option for one customised methodOption to customise methods list based on reagent typeNFC data transmissionUSB-C connectionAutomatic storage of the last 100 readings and protocols with time and date stampGLP compliant data backupMethods: M100, M101, M103, M110, M112, M330, M331Scope of supply: 3 x 24 mm vials with lid, 3 x stirring rods, syringe, cleaning brush, screwdriver, USB-C to USB-A cable, instruction manual, reagents, 2 x AA batteries
From €595.00*

Spectrophotometer NANOCOLOR® Advance
The spectrophotometer NANOCOLOR® Advance, with Reference Detector Technology (RDT), provides precise and reliable measurement and can be used in the entire spectrum of water and wastewater analysis. It can also be used mobile due to its rechargeable battery. With an additional 860 nm LED, the device determines the nephelometric turbidity during each measurement of a tube test and warns of incorrect results.Backlit colored 5" display with touch screenFully automatic cuvette recognition via the integrated 2D barcode scannerEvaluation of NANOCOLOR® tube tests (16 und 24 mm), standard tests (10, 20, 40, 50 mm) and VISOCOLOR® Powder PillowsOver 200 pre-programmed tests and special methods, 99 fully programmable methods, absorbance, transmission, factor, kinetics, 2-point calibration, scan, nephelometric turbidity measurement 1-1000 NTUScope of supply: Spectrophotometer NANOCOLOR® Advance, manual (quick start guide), protective covering, power supply unit with country specific adapters, USB stick, calibration cuvette, certificate, cleaning clothSpecificationsOptical system:Single beam photometer with grating monochromatorWavelength range:340 ... 800 nmWavelength accuracy:± 2 nmWavelength reproducibility:± 0.1 nmSpectral bandwidth: 4 nmPhotometric range:± 3.0 A in the range 340 ... 800 nmScattered light: 0.5 %Light source:Halogen lampData memory:1000 measured values / spectraInterfaces:2 x USB (Host), 1 x USB (Function)Dimensions (W x D x H): 280 x 325 x 130 mmWeigth: 3.8 kgPower supply:110 ... 240 V, 12 V 3A DCProtection class:IP67