Skip to main content Skip to search Skip to main navigation
Menu

Transfer membranes Amersham Protran

Description
Pure nitrocellulose with extreme mechanical stability - gives excellent useability. For protein transfer and DNA/RNA transfer techniques. Optimum signal/background ratio.

Properties
Dimensions (WxL): 600 x 300 mm
Length: 300 mm
Manufacturer Article Number: 10600033
Material: Cellulose nitrate (CN)
Pore size: 0,45 µm
Shape (Filters): Filter sheets
Width: 600 mm
Skip product gallery

Other customers also bought

Cytiva Europe GmbH

Cytiva Europe GmbH
Transfer membranes Optitran®
Webbing reinforced nitrocellulose.High mechanical stability for multiple hybridisations.
From €461.00*
Skip product gallery

Similar products

Storage boxes, HDPE with tightly closing LDPE lid
NaturalTemperature range (without mechanical stress) from -20 to 95°CAcid and chemical resistantSuitable for cold storage rooms and refrigeratorsStackableFood safe
From €2.30*

Sub Blot Systems omniBLOT
The omniBlot is an stand-alone unit for the tank-blot method. Each unit consists of an OmniPAGE tank and lid, a electroblotting insert as well as cassettes and fibre pads. The versatile design of the tanks and the matching lids are compatible with the vertical PAGE or IEF systems with the appropriate optional inserts.Mini system transfers up to 4 Mini gelsMini Wide system transfers up to 4 Mini Wide and 8 Mini gelsMaxi system transfers up to 4 Maxi gels, 8 Mini Wide and 16 Mini gelsRun-times ranging between 2 and 20 hoursRigid cassettes eliminate the formation of shadow bandsColour coded cassettes prevent reverse polarity for correct orientationCooling with cooling packs at high transmission intensitySpecificationsDimensions (W x D x H):Mini: 15 x 13 x 19 cm Mini Wide: 26 x 16 x 16 cm Maxi: 27 x 18 x 30 cmGel dimension:Mini: 8 x 8.5 cm Mini Wide: 16 x 8.5 cm Maxi: 16 x 17.5 cmMax. buffer volume:Mini: 1200 ml Mini Wide: 2800 ml Maxi: 6400 mlRun time:Mini: 1-2 h Mini Wide: 1-2 h Maxi: 5-20 hPower supply:100 V
From €873.00*

Membrane Tweezers
Swiss made. Made of austenitic steel. Non-magnetizable. Good corrosion resistance to most chemicals, salts and acids. Especially suitable for safe handling of transfer membranes.
From €23.10*

Blotting paper, medium absorbency
Recommended for blotting techniques with gels, like Southern, Northern and Western Blots, even Semidry-Blots of proteinsMade from ultrapure cotton linters and cellulose, entirely without additives to ensure that no contamination will occur during the transfer stepsTested specifically for chromatographic and blotting techniques to ensure high and uniform capillary actionsHigh wet strength for safe handlingFurther sizes on request.
From €304.10*

Blotting paper, high absorbency
Recommended for blotting techniques with gels, like Southern, Northern and Western Blots, even Semidry-Blots of proteinsMade from ultrapure cotton linters and cellulose, entirely without additives to ensure that no contamination will occur during the transfer stepsTested specifically for chromatographic and blotting techniques to ensure high and uniform capillary actionsHigh wet strength for safe handlingFurther sizes on request.
From €222.70*

LLG-Transfer membrane, supported nitrocellulose
Supported Nitrocellulose transfer membranes combine the binding characteristics of nitrocellulose membranes with the strength of nylon membranes. These membranes are used for DNA/RNA transfers requiring low background or for multiple hybridizations. For use with chemiluminescence and radiographic detection systems. BSA binding capacity up to 100 µg/cm2.The safety data sheets of these products are available under www.llg-labware.com.
From €399.00*

Blotting papers
High quality cotton papers with high absorbency for use in all blotting methods with gels.
From €321.79*

PBS, phosphate buffered saline
pH 7. In a HDPE bottle.
From €45.40*

Blocking solution for Western blot
An all-in-one blocking solution for Western blot analysis. In one step, blocking, primary and secondary antibodies hybridization as well as enhancing the signal.Enhance antibody signalUniversal antibody diluentEffective with any ECL substratesCompatible with PVDF and NC membraneImprove protein detection
From €190.40*

Transfer membrane, supported nitrocellulose
Supported Nitrocellulose transfer membranes combine the binding characteristics of nitrocellulose membranes with the strength of nylon membranes. These membranes are used for DNA/RNA transfers requiring low background or for multiple hybridizations. For use with chemiluminescence and radiographic detection systems. BSA binding capacity up to 100 µg/cm2.Signal word:H phrases:P phrases:
From €178.00*

Transfer membrane, PVDF
Hydrophobic Polyvinylidene Fluoride (PVDF) transfer membrane with high binding capacity and low background. Ideal for use in protein binding applications such as Western blots, solid phase assays and immunoblotting procedures. BSA binding capacity up to 125 µg/cm2
From €200.20*