TLC plates LuxPlate® Silica gel 60 F254
Merck KGaA
Product number:
6257506
Manufacturer:
Merck KGaA
Packaging information:
Description
Inorganic fluorescent indicators, green fluorescing.
Properties
Gel thickness mm: | 0,25 |
---|---|
Manufacturer Article Number: | 1.05805.0001 |
Material: | Glass |
Plate format cm: | 20 x 20 |
Buy | Unit price | Content | Delivery time | Preview | Product number |
---|
Skip product gallery
From
€653.00*
From
€213.00*
From
€45.30*
From
€732.00*
From
€259.00*
From
€293.00*
Other customers also bought
Merck KGaA
Merck KGaA
TLC plates Silica gel 60 RP-18 F254S
Inorganic fluorescent indicators, blue fluorescing, acid-stable.
Merck KGaA
Merck KGaA
TLC plates, Kieselguhr F254
Inorganic fluorescent indicators, green fluorescing.
Merck KGaA
Merck KGaA
TLC plates, Silica gel 60 F254
Inorganic fluorescent indicators, green fluorescing.
Merck KGaA
Merck KGaA
TLC plates Silica gel 60 RP-8 F254S
Inorganic fluorescent indicators, blue fluorescing, acid-stable.
Merck KGaA
Merck KGaA
TLC plates Silica gel 60 F254, with concentrating zone
Inorganic fluorescent indicators, green fluorescing.
Merck KGaA
Merck KGaA
TLC plates, Aluminum oxide 60 F254
Inorganic fluorescent indicators, green fluorescing.
Skip product gallery
SIL G unmodified standard silica layers for TLC, glass plates/ POLYGRAM®
From
€26.50*
Chromatography paper / Ion exchange papers
From
€60.30*
TLC plates Silica gel 60 RP-8 F254S
From
€732.00*
GLP plates silica gel 60
From
€324.00*
TLC plates Silica gel 60 F254, with concentrating zone
From
€259.00*
ALUGRAM® Nano-SIL unmodified Nano-silica layers for HPTLC
From
€271.00*
Aluminium oxide layers for TLC
From
€43.60*
Silgur unmodified standard silica layers with concentrating zone
From
€206.00*
Similar products
Support materials for TLC ready-to-use layersGlass plates: glass, ~ 1.3 mm thick, high requirements for weight, packaging and storage, ideal torsional strength, high temperature stability, susceptible to breakage, can not be cut with scissors, high resistance against solvents, mineral acids and conc. ammonia, suitability for aqueous detection reagents depends on the phasePOLYGRAM®: polyester, ~ 0.2 mm thick, low requirements for weight, packaging and storage, low torsional strength, max. 185 °C temperature stability, not susceptible to breakage, can be cut with scissors, high resistance against solvents, mineral acids and conc. ammonia, very suitable for aqueous detection reagentsALUGRAM®: aluminium, ~ 0.15 mm thick, low requirements for weight, packaging and storage, relatively high torsional strength, high temperature stability, not susceptible to breakage, can be cut with scissors, high resistance against solvents, low resistance against mineral acids and conc. ammonia, limited suitability for aqueous detection reagentsGlass plates, POLYGRAM®, ALUGRAM®Silica 60Specific surface (BET) ~500 m²/gMean pore size 60 ÅSpecific pore volume 0.75 ml/gParticle size 5 to 17 µmStandard gradeThickness of layer for analytical plates 0.25 mm, for preparative plates 0.5 and 1 mmFor 2 mm preparative layers a slightly coarser material is used, indicators: manganese activated zinc silicate with green fluorescence for short-wave UV (254 nm)Binders: highly polymeric products, which are stable in almost all organic solvents and resistant towards aggressive visualisation reagentsBinder system for Polygram® sheets is also completely stable in purely aqueous eluentsAvailable as glass plates, Polygram polyester sheets and Alugram aluminium sheetsAvailable with or without fluorescent indicator (UV 254)
Whatman chromatography papers are the most widely used papers for chromatography worldwide. This acceptance and usage reflects the purity, high quality and consistency of Whatman papers. These qualities are relied upon by chromatographers and essential to successful reproducible chromatography. Whatman chromatography paper media are made from specially selected cotton cellulose. They are rigorously quality controlled for characteristics important to the chromatographer and to ensure uniformity within the grade.1 Chr world standard chromatography paper. A smooth surface, 0.18 mm thick with a linear flow rate (water) of 130 mm/30 min. Good resolution for general analytical separations.3MM Chr widely used as a blotting paper, 3MM Chr is used in both electrophoresis and for general chemistry. A medium thickness paper (0.34 mm) used extensively for general chromatography and electrophoresis. Flow rate is 130 mm/30 min.3 Chr medium thickness paper (0.34 mm) with a flow rate of 130 mm/30 min. For general applications with medium/heavy solute loadings. Frequently used for separation of inorganic compounds and for electrophoresis.17 Chr thick (0.92 mm) and highly absorbent paper with a very high flow rate of 190 mm/30 min. Suitable for the heaviest loadings and ideal for preparative paper chromatography and electrophoresis.Ion exchange paperSG81: A unique paper (0.27 mm thick) combining cellulose and large pore silica gel. Suitable for separations in which both partition and adsorption are important, including the separation of phospholipids, steroids, phenols and dyes. Flow rate is 110 mm/30 min.
Inorganic fluorescent indicators, blue fluorescing, acid-stable.
Glass plates are additionally marked with article, batch and individual plate number. Ideal for GLP applications.Easy traceability, archiving and documentationWith or without fluorescent indicator F254
Inorganic fluorescent indicators, green fluorescing.
Support materials for TLC ready-to-use layersGlass plates: glass, ~ 1.3 mm thick, high requirements for weight, packaging and storage, ideal torsional strength, high temperature stability, susceptible to breakage, can not be cut with scissors, high resistance against solvents, mineral acids and conc. ammonia, suitability for aqueous detection reagents depends on the phasePOLYGRAM®: polyester, ~ 0.2 mm thick, low requirements for weight, packaging and storage, low torsional strength, max. 185 °C temperature stability, not susceptible to breakage, can be cut with scissors, high resistance against solvents, mineral acids and conc. ammonia, very suitable for aqueous detection reagentsALUGRAM®: aluminium, ~ 0.15 mm thick, low requirements for weight, packaging and storage, relatively high torsional strength, high temperature stability, not susceptible to breakage, can be cut with scissors, high resistance against solvents, low resistance against mineral acids and conc. ammonia, limited suitability for aqueous detection reagentsALUGRAM®Nano silica 60, specific surface (BET) ~ 500m²/g, mean pore size 60Å, specific pore volume 0.75ml/g, particle size 2 to 10µm. Indicator: manganese activated zinc silicate with green fluorescence for short-wave UV (254nm).Binder: highly polymeric product, which is stable in almost all organic solvents and resistant towards aggressive visualisation reagents. Narrow fractionation of the silica particles allows sharper separations, shorter developing times, shorter migration distances, smaller samples and an increased detection sensitivity compared to SIL G plates.Available as glass plates with or without fluorescent indicator (UV254).
Standard, rigid TLC plates in a choice of media, backing materials, and with dimensions as outlined below.*with 254 nm UV indicator
Support materials for TLC ready-to-use layersGlass plates: glass, ~ 1.3 mm thick, high requirements for weight, packaging and storage, ideal torsional strength, high temperature stability, susceptible to breakage, can not be cut with scissors, high resistance against solvents, mineral acids and conc. ammonia, suitability for aqueous detection reagents depends on the phasePOLYGRAM®: polyester, ~ 0.2 mm thick, low requirements for weight, packaging and storage, low torsional strength, max. 185 °C temperature stability, not susceptible to breakage, can be cut with scissors, high resistance against solvents, mineral acids and conc. ammonia, very suitable for aqueous detection reagentsALUGRAM®: aluminium, ~ 0.15 mm thick, low requirements for weight, packaging and storage, relatively high torsional strength, high temperature stability, not susceptible to breakage, can be cut with scissors, high resistance against solvents, low resistance against mineral acids and conc. ammonia, limited suitability for aqueous detection reagentsGlass platessilica 60, specific surface (BET) ~ 500m2/g, mean pore size 60Ä, specific pore volume 0.75ml/g, particle size 5.17µmkieselguhr zone for rapid sample application: because kieselguhr is completely inert towards a large number of compounds, the samples always from a narrow band at the interface of the two adsorbents, irrespective of shape, size or position of the spots in the concentrating zone. Separation then takes place inthe silica layer.available as glass plates with or without fluorescent indicator (UV254)