BOD measuring system OxiTop®-IDS IS for determination of aerobic degradation, Extension set for OxiTop®-IDS Set 6/12

Product number:
6311248
Manufacturer:
Xylem Analytics Germany (WTW)
Packaging information:
Weight:
9.5 kg
Description
These tests quantify the biological degradability of chemicals.
With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.
Please order CO2 absorber NHP 600 (9.303 403) separately.
The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.
Scope of supply: 6 resp.12 OxiTop®-IDS measuring heads, 6 resp.12 bottles, universal power adapter, 6 resp.12 rubber sleeves, 6 resp.12 magnetic stirring bars, stirring platform IS 6 resp. IS 12
With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.
- Respirometric degradability tests according to OECD 301F/DIN EN ISO 9408
- Versatile measurement by using the BOD special mode
- Measurement duration selectable (0.5 hours to 180 days)
- Bluetooth® connectivity
- Direct calculation of all results in the meter
- Representation of curves for monitoring
- Parallel measurement of different examinations and methods
- Export to data acquisition programs
Please order CO2 absorber NHP 600 (9.303 403) separately.
The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.
Properties
Manufacturer Article Number: | 209716 |
---|---|
Max. measured value: | 4000 mg/l |
Max. pressure: | 1250 hPa |
Max. voltage: | 240 V |
Measured range: | 0 ... 4,000 mg/l |
Measuring time: | 180 d |
Min. measured value: | 0 mg/l |
Min. pressure: | 500 hPa |
Min. voltage: | 100 V |
No. of measuring positions: | 12 |
Nominal volume bottle: | 510 ml |
Power supply: | 100 ... 240 V, 50/60 Hz |
Power supply frequency: | 50/60 Hz |
Pressure: | 500 ... 1,250 hPa |
Type: | OxiTop®-IDS IS 12 |
Type of auxiliary energy: | Battery/mains connection |